07/16 After fix of voltage dividor on GPIO6, had a trouble that it could not send a char to BT module, though could receive.
Found R8 had wrong 1K resistor and changed to 10K, after that it can send to the module again. Not sure how it had sent with the wrong 1K before.
2014-07-18 23:33:23 +06:00
07/18 On Linux, had an USB related trouble; keyobard or console didn't work for some reason. Changing PID cured this problem. Very annoying, took very long time before resolved it.
2014-07-17 13:59:22 +06:00
2014-07-01 01:29:45 +06:00
TODO
----
2014-07-17 13:59:22 +06:00
- Factroy reset doesn't work; need to test again. 10K pull-up is too high?
2014-07-07 08:02:13 +06:00
- Lipo voltage ADC sensing
- Lipo charger configuration: fast charge time: USB charger spec?
2014-07-01 01:29:45 +06:00
- Low voltage alarm: LED indcates voltage of Lipo
2014-07-01 07:19:14 +06:00
- CTS/RTS lines are needed? just connect in loop back if no flow control is needed.
- CTS is needed for waking up from deep sleep?
2014-07-01 01:29:45 +06:00
- Serial API callback when data are available/received(and when send buffer is available)
- Serial API instance several serial ports can be used
2014-07-07 08:02:13 +06:00
- DCDC converter: squeaky inducter with onsemi NCP1402
- Lipo charger MCP73831: needs capacitor 4.7uF *2
- Keymap layer bug: during space is pressed(mousekey) press Fn(HHKB) then release space before Fn, in result HHKB layer is locked(toggled) unintentionally.
2014-07-01 01:29:45 +06:00
2014-07-01 07:19:14 +06:00
DONE:
- USB connection check - 07.01
- BT on/off check: whether RX line is pulled up? - checking RTS 07.01
- USB/BT switching BT is on -> BT, BT is off -> USB - 07.01
- Under voltage lock out UVLO for protection of Lipo - Lipo has discharge protection at 3.100V 07.01
- Power saving: HHKB scan, BT radio control - 9h with 850mAh, this is enough 07.01
2014-07-07 08:02:13 +06:00
- Power selector doesn't work; Q4 MOSFET leaks from Lipo to USB power line. -- use Schottky instead 07/04
2014-07-01 07:19:14 +06:00
2014-07-18 23:33:23 +06:00
Lipo
----
Sparkfun Polymer Lithium Ion Battery 850mAh:
https://www.sparkfun.com/products/341
Lipo Cell spec:
https://www.sparkfun.com/datasheets/Batteries/063048%20Li-polymer.pdf
Protection spec:
http://dlnmh9ip6v2uc.cloudfront.net/datasheets/Prototyping/BatteryProtection.pdf
min typical max
over-charge 4.255 4.280 4.305
over-charge discover? 4.030 4.080 4.130
over-discharge 2.827 2.900 2.973
over-discharge discover 3.022 3.100 3.178
ADC voltage monitor: voltage divider 10K+10K(0.5)
ADC=V*0.5/2.56*1024
V ADC
------------------
4.20 0x347(839)
3.10 0x26b(619)
2014-07-01 01:29:45 +06:00
Configuration
-------------
Ver 6.15 04/26/2013
(c) Roving Networks
***Settings***
BTA=0006664B3AE3
BTName=tmkBT-3AE3
Baudrt(SW4)=115K
Mode =DTR
Authen=2
Bonded=0
2014-07-17 13:59:22 +06:00
Rem=000000000000
2014-07-01 01:29:45 +06:00
***ADVANCED Settings***
SrvName= keyboard/mouse
SrvClass=0000
DevClass=0000
InqWindw=0100
PagWindw=0100
CfgTimer=255
StatuStr=NULL
2014-07-17 13:59:22 +06:00
HidFlags=3c
2014-07-01 01:29:45 +06:00
DTRtimer=8
KeySwapr=0
***OTHER Settings***
Profile= HID
CfgChar= $
2014-07-17 13:59:22 +06:00
SniffEna=8010
2014-07-01 01:29:45 +06:00
LowPower=0
2014-07-17 13:59:22 +06:00
TX Power=0
2014-07-01 01:29:45 +06:00
IOPorts= 0
IOValues=0
Sleeptmr=0
DebugMod=0
RoleSwch=0
2014-07-17 13:59:22 +06:00
Serial connection
-----------------
2014-07-01 01:29:45 +06:00
Serial line: 115200bps, 8bit, 1-stopbit, non-parity, no flow control
SSP: 115200bps, 8bit, 1-stopbit, non-parity, no flow control(via Bluetooth)
2014-07-17 13:59:22 +06:00
To enter command mode disconnect the module from host and type '$$$'.(you will see 'CMD')
To exit type '---'(you will see 'END') and '+' to get local echo.
Setting command mode
--------------------
S-,tmkBT // Device name
SS,keyboard/mouse // service name
SM,4 // Auto Connect DTR mode
SW,8010 // Sniff enable 0x10*0.625ms=10ms; 50ms is laggish and not much power save
S~,6 // HID profile
SH,003C // HID register
SY,0004 // Transmit power
2014-07-01 01:29:45 +06:00
2014-07-17 13:59:22 +06:00
Other options:
2014-07-01 01:29:45 +06:00
SC,0000 // COD: 000005C0 (see HID spec/Bluegiga doc)
SD,05C0 // bit 12-8 7 6 5-0
// 00101 1 1 0
// peripheral pointing keybaord joystick, gamepad, ...
SM,6 // Pairing mode: auto connect
SM,4 // Master mode: Connection can be controled with GPIO6
HID profile
-----------
S~,6 HID profile
S~,0 SPP profile
R,1 reboot
Apple iOS
---------
Cannot supported without apple iAP authentication chip.
HID flag register
-----------------
SH,0200
GH
10 0000 0000(0200) default
00 0011 1000(0038) Combo
|| | | |\_\____ number of paired devices to which the module can reconnect
|| | | \_______ send out reports over UART (0xFF <len> <data>)
|| \__\_________ descriptor type
|\______________ toggle virtual keyboard on iOS when first connected
\_______________ Force HID mode if GPIO11 is high on power-up
Descriptor type:
0000: keybaord
0001: Game Pad
0010: Mouse
0011: Combo
0100: Joystick
1xxx: reserved
Out report - Indicator
----------------------
0xFE 0x02 0x01 <LED_state>
LED Status
----------
Configuring 10 times per sec
Startup/configuration timer 2 times per sec
Discoverable/Inquiring/Idle once per sec
Connected solid on
Pairing
-------
First, host initiates pairing process and once it is done, auto connect will work thereafter.
SM,3 Master mode
SM,4 Auto Connect DTR Mode uses GPIO6 to make and break connection(Mode =DTR)
confirm: auto connect works and control connection with GPIO6
SM,5 Auto Connect ANY Mode (Mode =ANY)
each time GPIO is set, make inquiry and connect to the first found device
SM,6 automatically reconnect(Mode =Pair)
confirm: auto connect works well but difficult to enter command mode.
Fast data mode
--------------
The module enters fast data mode after 'remote configuration timer' window is passed from power on.
In this mode the module does not accept '$$$' to enter command mode.
Power Management
----------------
Inquiry and Page window Idle or Active (3.1.1)
Downside: delay in discovery or connection time
SI, // set inquiry scan window(discovery) on/off duty?
SJ, // set page scan window(connection)
This reduces averaege power >20mA to 5mA(3mA in Sniff mode)
Sniff mode Transmit
Sniff mode is disabled by default and radio is active continuously when connected.(25-30mA)
In Sniff mode the radio wakes up intermittently and sleeps in very low power mode.(2mA)
SW,<val> // set interval timer(*0.625ms) 0000-7FFF
Deep sleep Idle (3.1.2)
In this mode the module shuts down completly and only draws about 300uA. To enable this set the most signifant bit(0x8000) of Sniff interaval timer.
2014-07-17 13:59:22 +06:00
SW,8320 // deep sleep enable(interval=0x320*0.625=500ms)
2014-07-01 01:29:45 +06:00
In normal sleep the firmware is still running in idle mode, and wakes up about 20 times per second to check ports, update LEDs, etc. During deep sleep, the firmware actually stops runnig some tasks and the LEDs only update about once per second.
To wake from deep sleep there are three ways: (in worst case wake up takes 5ms)
*send a charactor to the UART(first charactor will be lost)
*toggle CTS low to high and wait 5ms
*wake automatically every slot time(<val>*0.625ms)
Once the radio is awake it stay active for exactly 1 second of inactivity and then sleeps again.
Downside: latency and data loss
Disable Output driver Idle or Active (3.1.3)
S%,1000 // set all GPIO pins(0-11) to inputs.
Lower Transmit Power Idle or Active (3.1.4)
SY,<hex> // transmit power setting(takes effect after a power cycle and reboot)
Downside: reducing effective range
Optimizig for Latency
---------------------
By default the firmware is optimized for throughput.
SQ,16 // set latency bit
SQ,0 // unset latency bit
Configuration timer settings
----------------------------
Remote configuration is used for the module to be configured with various commands over Bluetooth(SPP profile only?).
The module has remote configuration timer to allow remote configuration over Bluetooth after power up in Slave mode. In Master modes the remote configuration timer is set to 0(no remote configuration). (In Trigger Master mode the timer is used as an idle timer to break the connection after time expires with no charactors receive.)
ST,0 // no remote, no local when connected
ST,<1-252> // local and remote with timeout in seconds from power up
ST,253 // local only without timeout
ST,254 // remote only without timeout
ST,255 // local and remote without timeout
Android
-------
3.7.1.5 Note: To connect with Android phone the modules must wake up 11ms every 2.5seconds.
Commands
--------
SC,
SM,<val>
SD,
SP,<string> Pin code(alpahnumeric)
SQ,<mask> Special configuration(GPIO, discovery mode, low latency, reboot, UART)
SR,<hex> Store remote address
SR,Z Erase all address
SS,<string> Set service name(1-20)**
ST,<val> Remote configuration timer(Master:0, Slave:0-255, Triger:as idle timer)
SU,<val> UART baud rate
SW,<val> low-power sniff mode** deep sleep and wake up every 625us * <val>
SX,<0|1> bonding enable only acceps device that matches the stored address
SY,<hex> power setting**
SZ,<val> non-standard raw baud rate <val>=baud*0.004096
S~,<val> Profile 0:SPP, 5:APL, 6:HID
S-,<string> Device name -15 alphanumeric charactors
S?,<0|1> role switch enable
S$,<char> command mode char
$|,<hex> low-power connect mode deep sleep/active(discoverable and connectable) cycle
D display basic setting
E display extended setting
GB display the device's Bluetooth address
GF display Bluetooth address of connected device
GK show connection status
GR show remote address for reconnecting
G& show GPIO pin
G<char> show stored setting
+ toggle local echo on/off
& show GPIO 3,4,6,7(DIP switch)
C connect to stored remote address
C,<address> connect last address
CFI connect and go into fast data mode
CFR connect and go into fast data mode
CT,<address>,<val> connect to the address and disconnect after val?
F,1 fast data mod:
H display help
I,<time>,<cod> inquiry scan with <cod>
IN
IQ scan
IS inquiry scan with 001F00
J hide pin code
K, kill disconnects current connection
L link quality
M show modem signlal status
O display other settings
P,<car> pass through?
Q quiet mode make the module not discoverable
Q,0 discoverable and connectable
Q,1 not discoverable and not connectable
Q,2 not discoverable and connectable
Q,? display current quiet mode
R,1 reboot
T,<0|1> pass received data while in command mode
U,<baud>,<parity> change UART setting tentatively
V display firmware version
W wake from quiet mode enable discovery and connection
Z deep sleep mode(<2mA)